行业分类
基于CDEGS对降低变电站接地电阻的方法研究
日期:2018-10-16 16:41  点击:702
摘要:高土壤电阻率地区的接地设计和降阻措施一直是研究接地工作者关心的问题。本文利用了加拿大公司开发的CDEGS软件包中的RESAP和MALZ模块,用RESAP模块计算土壤分层情况,用MALZ模块分别模拟了接地网的埋深位置、接地网的网格间距、接地网的尺寸、增加接地网的垂直接地棒以及垂直接地棒位置和深度等对接地电阻的影响,并比较了各种方法的降阻效果,总结出了在高土壤电阻率地区,不同土壤的分层结构下如何更好的使用各种降阻方法使接地电阻降到最小。
关键词:接地电阻;接地网;CDEGS;降阻措施
Research on Method of Decreasing Substation Grounding Resistance Based on CDEGS
Quan Xuezheng
(Xizang Agriculture and Animal Husbandry College, Linzhi 860000,Tibet,China)
Abstract:Because the grounding design and resistance reduction measures in high soil resistivity areas have always been a concern for grounding workers. In this paper, the RESAP and MALZ modules of the CDEGS software package developed by the Canadian company, the RESAP module were used to calculate the soil stratification, the MALZ module was used to simulate the depth of the grounding grid, the grid spacing of the grounding grid, and the size of the grounding grid. , increase the influence of the grounding resistance on the vertical ground bar and the vertical ground bar position and depth of the grounding grid, and compared the resistance reduction effect of various methods,the conclusion that how to use various resistance-reduction methods to minimize grounding resistance in high soil resistivity areas in different soil layers.
Keyword: grounding resistance;grounding grid;CDEGS;Resistance reduction method
引言
变电站接地网接地是维护电力系统安全可靠运行、保障人员和设备安全的根本保证和重要措施【1】。接地电阻与电学中导体电阻的物理概念是完全不同的。导体电阻指的是导体自身的有效电阻,而接地电阻主要是指接地电极周围土壤的电阻【2】。变电站接地网的接地电阻值是变电站接地系统的重要技术指标,是衡量接地系统有效性、安全性以及鉴定该系统是否符合要求的重要参数【3】。由于接地装置周围土壤电阻率的高低在很大程度上决定了接地电阻的大小,建在高土壤电阻率地区的变电站接地电阻一般很难满足要求。通过收集资料了解到降低接地电阻的方法有扩大接地网尺寸及增加接地网埋深,加设垂直接地极,局部换土,深井接地,接地降阻剂,离子接地极等。【4-5】本文利用接地软件CDEGS,模拟了接地网埋设位置、接地网网格间距、接地网的尺寸和增设垂直接地极及垂直接地极位置和深度等对接地电阻的研究。

1 CDEGS简介
CDEGS是由加拿大SES公司出品。CDEGS软件包有RESAP、MALT、MALZ、SPLITS、TRALIN、HIFREQ、FCDIST、FFTSES共8个功能模块。该软件可用于研究接地、电磁场、交直流电磁兼容,以及阴极保护等。